Товары
Связаться с нами
Фильтр с защитой от дождя
  • NTL-F152-W

наименование товара:

Модель продукта:


Wechat:15088970667

WhatsApp:008615088970667

Отправить запрос

  • параметры

Technical Data

NTL-FF152W
Axial fan, ball bearingservice life L10 at +40°C (+104°F): min. 37,000 h fan body aluminium, rotor metal
Connection2 stranded wires, 160mm
Enclosure cut-out125 x 125mm
Mounting frameScrew Fixing Type, Easy to open the cover.
Filter matG4 acc. to DIN EN 779, filtering degree 94%
Filter materialNew ABS material confirm to RoHS, Fireproof or not fireproof can be choose
Operating/Storage temperature-40 to +70°C (-40 to +158°F)
Operating/Storage humiditymax. 90% RH (non-condensing)
Protection type/Protection classIP55 / I (earthed)
Noteother voltages on request


Technical Parameters

ModelPower
Supply
Net
Weight
(kg)
Fan Size
Matched
(mm)
Air Flow Rate
(free blow)
(m3
/h)
Power
Consumption
(W)
Current
Consumption
(A)
Noise
Level
(dBA)
F125W-0.156without fan----
125W230A230VAC0.53120×120×2596/11214/120.0739/42
125W230B230VAC0.64120×120×38138/16219/150.11/0.10543/48
125W115A115VAC0.53120×120×2596/11214/120.1439/42
125W115B115VAC0.64120×120×38138/16217/140.24/0.19843/48
125W1212VDC0.4068120×120×38179.767.20.648
125W2424VDC0.4068120×120×38179.769.60.448

Normally is airflow direction"Out", if you need airflow direction "In", when place order, please advice.

  • Структурная Диаграмма

Time-saving assembly and maintenance

Natural's fan filters are easily installed by one person from outside the cabinet.

1.) Make cut-out in the cabinet wall. The cut edge of the cabinet opening should be free of dirt, filings and grease. A template for the enclosure cut-out is included in the delivery of the fan filter.

2.) Remove protective film from the sealing strips on the mounting frame. Press mounting frame into the cabinet opening. The frame stays permanently in the cabinet. (For size 176mm and up we recommend additional screw fixing.)

3.) Electrically connect the axial fan using the clip connectors. Push the unit into the mounting frame. Fix using screws.

4.) Insert the filter mat in the hood. Clip on. Finished.

Changing the filter mat or fan is quickly done by one person. To change the filter mat simply remove the filter hood, insert the new mat and snap the hood back again. No tools required. Maintenance of the fan can easily be done without removing the mounting frame (2).

Rain-Resistance Exit Filter


Exit Filter with Rain-Resistance Hood NTL-F125-W

Art. No.Depth in enclosureEnclosure cut-outWeight (approx.)Filter mat
86277116mm125 x 125mm + 0.40.4kgG4 acc. to DIN EN 779, filtering degree 94%


  • сертификация
  • Filter Fan CE-EMC

    Filter Fan CE-EMC

  • Filter Fan CE-LVD

    Filter Fan CE-LVD

  • Filter Fan RoHS

    Filter Fan RoHS

  • Filter Fan Reach

    Filter Fan Reach

  • Filter Fan IP54

    Filter Fan IP54

  • Filter Fan IP55

    Filter Fan IP55

  • заявка

Fan filters are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the electronic components from overheating. These filter fans are intended for outdoor use. The plastic used for the hood is highly UV light resistant.

  • Video

Поле для комментариев



sinqury
Подписывайтесь на нас: facebook Twitter Linkedin Pinterest GooglePlus